TE Connectivity - Circuit Breakers - W23-X1A1G-10
Genuine OEM Parts
Description: Circuit Breakers
Part Number: W23-X1A1G-10
Product Overview
The W23-X1A1G-10 is a 10A toggle/push/pull actuator Thermal Circuit Breaker, calibration will continuously carry 100% of rating, may trip between 101% and 134% of rating at 25°C, must trip at 135% in one hour. Ten times rated current is resettable overload capacity, over 1500V RMS dielectric strength, endurance cycling is more than 6000 cycles at 100% of rating or 10000 mechanical cycles. Threaded bushing 3/8-inch diameter panel mounting, 250VAC/50VDC voltage rating. Screw terminals situated 90° to each other with #8-32 screws and washers installed and also two hex nuts or lock washer installed.
Characteristics
| Body Style | : | Single Pole Type | |
| Bushing Length | : | 0.388" Inches Nominal | |
| Body Length | : | 1.375" Inches Nominal | |
| Body Width | : | 0.690" Inches Nominal | |
| Center to Center Distance Between Terminals Parallel to Length | : | 1.020" Inches Nominal | |
| Fragility Factor | : | Moderately Rugged | |
| End Item Identification | : | Nsn 2320 01 530 3843, Truck Cargo | |
| Mounting Surface to Terminal End Distance | : | 2.035" Inches Nominal | |
| Pole Quantity | : | 1 | |
| ARC Quenching Method | : | AIR | |
| Mounting Facility Type and Quantity | : | 1 Threaded Bushing | |
| Storage Type | : | General Purpose Warehouse | |
| Thread Quantity per Inch | : | 24 | |
| Maximum Continuous Load Current Rating per Pole | : | 10.0 amperes AC and 10.0 amperes DC single location | |
| Operating Voltage Type and Rating per Pole in Volts | : | 250.0 AC and 50.0 DC Single Location | |
| Maximum Interrupting Capacity Current Type and Rating per Pole in Amps | : | 1000.0 AC and 2500.0 DC Single Location | |
| Circuit Protection Type | : | Overcurrent Single Location | |
| Trip Release Method | : | Thermal Single Location | |
| Trip Release Characteristic | : | Time Delay Single Location | |
| Ultimate Trip Rating of Continuous Current Rating per Pole in Percent | : | 135.0 Single Location | |
| Reset Method | : | Manual | |
| Main Contact Tripping Mechanism Type | : | Trip Free | |
| Manual Actuator Type and Quantity | : | 1 Push-Pull | |
| Actuator Function | : | Trip-reset | |
| Actuator Position Designation | : | At Pole One | |
| Internal Trip Release Configuration | : | Series Trip Single Location | |
| Nominal Thread Size | : | 0.375" Inches | |
| Trip Delay Time in Seconds per Rated Continuous Current | : | 6.000 Minimum at 200 pct and 22.000 Maximum at 200 pct Single Location | |
| Enclosure Protection Type for Which Designed | : | Humidity Resistant and Salt Spray Proof and Shock Resistant and Vibration Resistant | |
| Trip Release Ambient Temp Rating | : | 25.0°C Nominal Single Location | |
| Unpackaged Unit Weight | : | 2.000 Ounces Nominal | |
| Case Material | : | Plastic | |
| Frequency in Hertz | : | 400.0 Single Location | |
| Thread Series Designator | : | UNF | |
| Terminal Type and Quantity | : | 2 tab W/screw |
**Technical Datasheet [Click Here]